qcx#h0_en2_kvi#c6.dat

Charge Exchange Cross Sections

Ion
C6+
Energy Range
0.010 keV/amu → 100 keV/amu

ADF01

Filename
qcx#h0_en2_kvi#c6.dat
Full Path
adf01/qcx#h0/qcx#h0_en2_kvi#c6.dat
Download data
C6+ + H0(n=2) → C5+ + H+total
C6+ + H0(n=2) → C5+(n=6) + H+n-resolved
C6+ + H0(n=2) → C5+(6s) + H+nl-resolved
C6+ + H0(n=2) → C5+(6p) + H+nl-resolved
C6+ + H0(n=2) → C5+(6d) + H+nl-resolved
C6+ + H0(n=2) → C5+(6f) + H+nl-resolved
C6+ + H0(n=2) → C5+(6g) + H+nl-resolved
C6+ + H0(n=2) → C5+(6h) + H+nl-resolved
C6+ + H0(n=2) → C5+(n=7) + H+n-resolved
C6+ + H0(n=2) → C5+(7s) + H+nl-resolved
C6+ + H0(n=2) → C5+(7p) + H+nl-resolved
C6+ + H0(n=2) → C5+(7d) + H+nl-resolved
C6+ + H0(n=2) → C5+(7f) + H+nl-resolved
C6+ + H0(n=2) → C5+(7g) + H+nl-resolved
C6+ + H0(n=2) → C5+(7h) + H+nl-resolved
C6+ + H0(n=2) → C5+(7i) + H+nl-resolved
C6+ + H0(n=2) → C5+(n=8) + H+n-resolved
C6+ + H0(n=2) → C5+(8s) + H+nl-resolved
C6+ + H0(n=2) → C5+(8p) + H+nl-resolved
C6+ + H0(n=2) → C5+(8d) + H+nl-resolved
C6+ + H0(n=2) → C5+(8f) + H+nl-resolved
C6+ + H0(n=2) → C5+(8g) + H+nl-resolved
C6+ + H0(n=2) → C5+(8h) + H+nl-resolved
C6+ + H0(n=2) → C5+(8i) + H+nl-resolved
C6+ + H0(n=2) → C5+(8j) + H+nl-resolved
C6+ + H0(n=2) → C5+(n=9) + H+n-resolved
C6+ + H0(n=2) → C5+(9s) + H+nl-resolved
C6+ + H0(n=2) → C5+(9p) + H+nl-resolved
C6+ + H0(n=2) → C5+(9d) + H+nl-resolved
C6+ + H0(n=2) → C5+(9f) + H+nl-resolved
C6+ + H0(n=2) → C5+(9g) + H+nl-resolved
C6+ + H0(n=2) → C5+(9h) + H+nl-resolved
C6+ + H0(n=2) → C5+(9i) + H+nl-resolved
C6+ + H0(n=2) → C5+(9j) + H+nl-resolved
C6+ + H0(n=2) → C5+(9k) + H+nl-resolved
C6+ + H0(n=2) → C5+(n=10) + H+n-resolved
C6+ + H0(n=2) → C5+(10s) + H+nl-resolved
C6+ + H0(n=2) → C5+(10p) + H+nl-resolved
C6+ + H0(n=2) → C5+(10d) + H+nl-resolved
C6+ + H0(n=2) → C5+(10f) + H+nl-resolved
C6+ + H0(n=2) → C5+(10g) + H+nl-resolved
C6+ + H0(n=2) → C5+(10h) + H+nl-resolved
C6+ + H0(n=2) → C5+(10i) + H+nl-resolved
C6+ + H0(n=2) → C5+(10j) + H+nl-resolved
C6+ + H0(n=2) → C5+(10k) + H+nl-resolved
C6+ + H0(n=2) → C5+(10l) + H+nl-resolved
 + 6     H + 0 (2) / receiver, donor (donor state n=2)       /        /
-----------------------------------------------------------------------------------------------------
  Source:  The data consists of results of CTMC calculations made at the University of Missouri over 
              the period 1995-97.
     
  Comments:  At this time, no direct comparison with other results is available for checking the 
             quality of the nl selective cross-sections except for Li+3 for which results are given
             in a recent hidden curve crossing calculation by Janev et al. (1996).  Large differences
             are observed in both the magnitude and energy dependence.  From inspection of the total
             cross-sections, we have the strong impression that the CTMC data should be preferred.
             In a plot of the scaled total one-electron capture cross-sections (sigma_tot(16q)^-1)
             versus scaled energy (4Eq^-1/2), the total cross-sections should be approximately the
             same for all systems (Janev, 1991) at least for q>3.  In these scaled units, a 
             recommendation by Janev and Smith (1995) has been presented.  The CTMC data are all close 
             to this curve except at lower energies.  The hidden curve crossing data for Li+3 deviate
             from this curve.  Molecular orbital calculations by Errea et al. (1996) for B+5 are in
             good agreement with the corresponding CTMC data.  For He+2, the recommendation of Janev
             and Smith is based on the calculations of Harel and Jouin (1990) and it is completely
             different from the CTMC results for He+2, especially at the lower energies.  A reason
             for this huge difference is hard to see.  It may be the extremely strong resonant 
             nature of the electron capture at low collision energies.  Resonant transfer from H(n=2)
             in collsions with He+2 would necessarily mean that the electron ends up exactly between
             the n=3 and n=4 levels of He+1.  Therefore electron capture may be blocked. To what extent
             this is well described by the CTMC method is still a point of discussion.  For higher
             charged receiver ions, levels are resonantly present.  Except for He+2 at low energies, 
             we recommend use of the present CTMC data. 

             The data was assembled as ADAS data files of type adf01 at JET Joint Undertaking in the
             period 2-3 June 1997.    

  Authors:  F. W. Bliek*, R. Hoekstra*, R. E. Olson#
                  * KVI, Groningen, Netherlands
                  # University of Missouri, Rolla, USA. 

  Date:  9 June 1997.

  Updates:

  Cross sections for n-l=9-8 and n-l=10-9 at the highest energy and n-l=10-9 at the second highest
  energy were zero. These have been set to the difference between the toal n cross section and the
  sum of the l=0 to l=n-2 partial cross sections.

  Martin O'Mullane
  22-09-2009

------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------
---------------------------------------------------------------------------------

Dependents

Contributors

  • Kernfysisch Versneller Instituut
  • Martin O'Mullane
  • Transitions
  • Comments
  • Origins

Data Classes